Send inquiry
Model Number: ACE 6k~10KVA (1:1)
Brand Name: AWP
Key Specifications/Special Features:
Features:Single/single-phase, three/single-phase models with on-line double conversion technologyDSP (digital signal processors) technologySuitable for all kinds of loads (resistive, inductive and non-linear loads etc)High overload capability (up to 150%)Bypass dual DSP control design to enhance more reliability
Supports dual input, hot standby in series
Redundant and parallel able with advanced parallel current-sharing control technology
Cold start and mains start function
High charging capability: 2/4/6/8/10/12A selectable (standard), 14/16/18/20/22/24A selectable (options)
Standard configuration with output isolation transformer
Superior protection (surges, short-circuit, overvoltages, under voltages, overcharge, reverse connection protection)
Advanced communications (RS232 and USB ports (standard), SNMP, dry contacts and RS485 (options))
Other options (parallel kits, input isolation transformer, bypass isolation transformer and harmonic suppressor)
| Model | ACE 06 (1:1) |
ACE 10 (1:1) |
ACE 10 (3:1) |
ACE 15 (3:1) |
ACE 20 (3:1) |
ACE 30 (3:1) |
|||
| Capacity | 6 kVA 4800W |
10kVA 8kW |
10kVA 8kW |
15kVA 12kW |
20kVA 16kW |
30kVA 24kW |
|||
| Input | |||||||||
| Rated voltage | 220/230/240V AC | 380/400/415V AC | |||||||
| Voltage range | 165-275V AC | 285-475V AC | |||||||
| Rated frequency | 50-60Hz | ||||||||
| Frequency range | 40-70Hz | ||||||||
| Frequency tracking range | ± 5%Hz | ||||||||
| Bypass | |||||||||
| Rated voltage | 220/230/240V AC | ||||||||
| Overload capability | load current < 150% rated current: long time running 150% ≤ load current < 200%: 1 minute 200% rated current ≤ load current: 200 minutes |
||||||||
| Batteries | |||||||||
| Battery voltage | 192V DC | ||||||||
| Battery type | VRLA AGM maintenance-free lead based | ||||||||
| Number of battery | 12V x 16 pieces | ||||||||
| Charging voltage | 220V DC | ||||||||
| EOD | 168V dc | ||||||||
| Charging current | Default 8 A (2/4/6/8/10/12 A selectable) | ||||||||
| Output | |||||||||
| Rated voltage | 220/230/240V AC | ||||||||
| Power factor | 0.8 | ||||||||
| Waveform | sinusoidal | ||||||||
| Rated frequency | 50/60Hz (settable) | ||||||||
| Frequency precision | mains mode: track bypass input in the state of synchronization battery mode: 50/60 ± 0.1Hz |
||||||||
| Voltage precision | ± 1% | ||||||||
| Recoverytime of transientvoltage | < 20 minutes | ||||||||
| Crest factor | 3:1 | ||||||||
| THDV | ≤ 3% (linear load); ≤ 6% (non-linear load) | ||||||||
| Overload capability | Load ≤ 105%: long time running 105% load ≤ 125%: transfer to bypass in 10 minutes 125% load ≤ 150%: transfer to bypass in 1 minute 150% load ≤ 200%: transfer to bypass in 200 minutes 200% load: transfer to bypass in 100 minutes |
||||||||
| Others | |||||||||
| Transfer time | 0 minute | ||||||||
| Protections | Overload, surge, short circuit, over/under-voltage, battery overcharge/over-discharge, over-temperature | ||||||||
| Communications | RS232/USB (standard) RS485/SNMP/dry contacts (optional) |
||||||||
| Operating temperature | 0 to 40C | ||||||||
| Storage temperature | -25to 55 C (without batteries) | ||||||||
| Relative humidity | 0 to 95% (non-condensing) | ||||||||
| Operating altitude | ≤ 1000m (derating 1% for each additional 100m) | ||||||||
| Noise level | < 60dB (at 1 minute) | ||||||||
| MTBF | MTBF >20,0000H | ||||||||
| MTTR | MTTR <0.5H | ||||||||
| IP rating | IP20 | ||||||||
| Dimensions |
210 x 585 x 590mm | 310 x 600 x 880mm | 400 x 815 x 1100mm | ||||||
| Net weight | 54kg | 96kg | 130kg | 201kg | 230kg | 277kg | |||
| Gross weight | 64kg | 108kg | 142kg | 216g | 245kg | 292kg | |||
Shipping Information:
- FOB Port: Shenzhen
- Lead Time: 15 - 30 days
Main Export Markets:
- Asia
- Australasia
- Central/South America
- Eastern Europe
- Mid East/Africa
- North America
- Western Europe